1. CUT-IN pressure — turns the pump ON When you open a tap, water pressure in the pipe drops. For example, if the switch is set to: CUT-IN = 2.0 bar (≈29 PSI) When pressure falls to around 2.0 bar, the diaphragm inside moves and the electrical contacts close → pump ON. 2. CUT-OUT pressure — turns the pump OFF When the pump runs, pressure rises. For example: CUT-OUT = 3.5 bar (≈51 PSI) When pressure reaches about 3.5 bar, the internal mechanism moves the contacts open → pump OFF. So it works like this: Tap opens → pressure ↓ → 2.0 bar → ON → pressure ↑ → 3.5 bar → OFF The difference between the two settings is called the differential: 3.5 − 2.0 = 1.5 bar (≈22 PSI) Adjustment Most switches of this style have springs/adjustment screws inside. Generally: Main spring → raises or lowers the overall ON/OFF pressure range.